800KW Cummins Diesel Generator EPA Tier 2 (Standby)

$171,315.00

1 or 3 Phase?

Our recommendation: Choose 1-phase if you are powering a home, RV, or small business. Choose 3-phase if you are powering machinery, industrial HVAC systems, or large motors. If you have a mix of loads, a 3-phase generator can often provide both, but will require balancing.

Require Automatic Switching?

An Automatic Transfer Switch (ATS) is an intelligent, self-acting device that monitors utility power and automatically switches a facility’s electrical load to a generator during a power outage.

Order total:
Categories: Tags: SKU: WDG-800-CUM-S

Description

800 kW Cummins Diesel Generator EPA Tier 2 (Standby)

The 800 kW Cummins Diesel Generator (Standby) – EPA Tier 2 is a high-capacity standby power solution designed for emergency and backup power applications. Rated at 800 kW / 1000 kVA, the generator operates at 60 Hz and can be configured for single-phase or three-phase operation, with voltage customizable to suit the application.

At the heart of the generator is a Cummins KTA38-G2 diesel engine. This heavy-duty 12-cylinder, 37.8-liter engine features turbocharging and aftercooling, water cooling, electronic governing, and an operating speed of 1800 RPM. The Cummins engine data sheet further specifies a 4-cycle, 60° Vee configuration with a 6.25 × 6.25-inch bore and stroke and 14.5:1 compression ratio.

Electrical power is produced by a Stamford S6L1D-C self-excited, brushless alternator with 0.8 power factor, AVR voltage regulation, Class H insulation, and IP23 protection. The included Stamford technical data shows that the alternator platform supports a 1000 kVA / 800 kW continuous Class H rating at 480V and 60 Hz, matching the generator’s 800 kW output requirement.

Generator control is provided by the DEIF AGC 150, which combines genset protection and control with advanced power-management capabilities. The controller supports automatic mains failure applications, synchronization, breaker control, load sharing, and generator power management.

The generator is housed in a silent, weatherproof enclosure and incorporates a large 660-gallon fuel tank for extended standby capability. Additional equipment includes dual MCCBs, UL main breaker and wiring, UL battery charger, UL coolant heater, UL battery disconnect switch, permanent-connection base entry, and 2-wire remote start.

Key Features

  • 800 kW / 1000 kVA Standby Power
  • Cummins KTA38-G2 diesel engine
  • Stamford S6L1D-C brushless alternator
  • DEIF AGC 150 generator controller
  • EPA Tier 2 | 60 Hz | 1800 RPM
  • Silent, weatherproof enclosure
  • 660-gallon fuel tank
  • Customizable voltage with single- or three-phase options

Why Choose the 800 kW Cummins Diesel Generator?

  • High-Capacity Standby Power: Delivers 800 kW / 1000 kVA for large commercial and industrial standby applications.
  • Cummins KTA38-G2 Engine: Powered by a robust 37.8-liter V12 diesel engine with turbocharging, aftercooling, electronic governing, and water cooling.
  • Stamford Alternator: The S6L1D-C provides a brushless design, Class H insulation, AVR regulation, IP23 protection, and a 0.8 power factor.
  • Flexible Electrical Configuration: The generator specification allows customized voltage and either single-phase or three-phase configurations.
  • Advanced DEIF Controls: The AGC 150 can protect and control the genset and generator breaker while supporting synchronization, automatic mains failure, and more advanced power-management configurations.
  • Large Integrated Fuel Capacity: A 660-gallon fuel tank supports extended operation during utility outages.
  • Standby-Focused Configuration: Cummins defines the KTA38-G2 standby rating specifically for emergency power during utility outages.
  • Commercial Installation Features: UL main breaker and wiring, battery charger, coolant heater, battery disconnect, permanent-connection base entry, and 2-wire remote start are included in the generator specification.

Common Applications

  • Emergency standby power
  • Commercial buildings
  • Industrial facilities
  • Manufacturing plants
  • Warehouses and distribution centers
  • Data and communications facilities
  • Large office and business facilities
  • Critical infrastructure
  • Municipal and government facilities
  • Water and wastewater facilities
  • Large-scale backup power systems
  • Facilities requiring high-capacity emergency generation

Buyer’s Guide – How to Choose the Right Generator

Need guidance on size, voltage, phase or installation? Visit our Ultimate Diesel Generator Buyer’s Guide for helpful advice.

Contact Us

Phone: 423.220.3500
Email: sales@wholesale-generators.com
Request a Quote: Contact Form

Warranty & Lead Time

Lead Time: 90 Day Delivery Estimate – Call to see if this product is in stock
Warranty: 2 Years / 2000 Hours on parts

Every product is tested before shipping.


 

Spec Sheets

800KW Cummins Diesel Generator EPA Tier 2 Standby Cut Sheet